forede® AUTOMATIC TRACKING FIRE MONITOR is a cutting-edge device with a range of advanced features. The single strand incoming line with anti-winding design ensures smooth operation. The integrated design without a junction box and the smaller size of the single tube spherical appearance make it convenient to install and use.
The hard anodized surface of the monitor makes it durable and suitable for harsh environments. Made of high-strength nylon material, the monitor is fire retardant for added safety. The ring alarm lamp provides visual alerts in case of a fire emergency. The removable sensor guard case allows for easy maintenance.
The laser positioning indication and high-definition screen monitoring make it easier to track fires and ensure prompt action. Overall, the forede® AUTOMATIC TRACKING FIRE MONITOR is a reliable and efficient device for fire protection.
Key Features
- Single strand incoming line, anti-winding design;
- Integrated design without junction box;
- Single tube spherical appearance, smaller size;
- Hard anodized surface, more suitable for harsh environments;
- Made of high-strength nylon material, fire retardant;
- Ring alarm lamp;
- Removable sensor guard case;
- Laser positioning indication, high-definition screen monitoring;
| Model |
ZDMS0.6 /5S |
ZDMS0.8 /10S |
| Control |
Automatic, Control box |
Automatic, Control box |
| Working Pressure |
6 bar |
8 bar |
| Flow Rate |
300 LPM |
600 LPM |
| Max Protection Radius |
30 m |
35 m |
| Monitoring Radius |
50 m |
50 m |
| Mounting Height |
6~15 m |
6~15 m |
| Targeting Time |
≤30 S |
≤30 S |
| Swing Horizontally |
360° |
360° |
| Elevate Vertically |
-90° to +30° |
-90° to +30° |
| Inlet |
2" BS Flange, others size and standard available |
2" BS Flange, others size and standard available |
| Detector Type |
Infrared ray & UV sensor technology |
Infrared ray & UV sensor technology |
| Installation |
Hanging |
Hanging |
1. What Does "Automatic Tracking" Mean for This Monitor?
Q: What does the "automatic tracking" feature do?A: It uses infrared/UV sensors to detect fires, then automatically swivels (360° horizontal, -90° to +30° vertical) to aim at the fire and start spraying. It responds to fires without manual input-ideal for unattended or large spaces.
2. How Does the "Anti-Winding Design" Work?
Q: What's the benefit of the "single strand incoming line + anti-winding design"?A: The anti-winding design ensures the monitor can rotate 360° freely without tangling the cable/pipe (from the single incoming line). This prevents damage to connections and lets the monitor spin unobstructed while tracking fires.
3. Purpose of the "Ring Alarm Lamp"
Q: What does the ring alarm lamp do?A: The lamp activates when the monitor detects a fire-alerting on-site personnel that a fire has been identified and the system is actively responding (spraying/aiming).
4. Choosing Between ZDMS0.6/5S and ZDMS0.8/10S
Q: How do I pick between the ZDMS0.6/5S and ZDMS0.8/10S models?A: Select based on your space and flow needs:
- ZDMS0.6/5S: 300 LPM flow, 30m protection radius (ideal for smaller areas: small warehouses, compact workshops).
- ZDMS0.8/10S: 600 LPM flow, 35m protection radius (better for larger spaces: big factories, expansive storage areas).
5. What Is "Laser Positioning Indication"?
Q: What's the laser positioning feature used for?A: The laser marks the exact target point of the monitor's spray. It helps verify the monitor is aimed correctly at the fire, or assists with manual adjustments (if needed) for precise targeting.
6. Ideal Mounting Height (6-15m) Explanation
Q: Why is the mounting height 6-15m, and what happens if I mount it outside this range?A: 6-15m is optimal: it lets the infrared/UV sensors cover a wide area (up to 50m monitoring radius) while keeping the monitor out of immediate fire reach. Mounting too low limits coverage; too high may reduce detection accuracy.
7. Targeting Time (≤30s) Meaning
Q: What does "targeting time ≤30s" mean for fire response?A: It means from fire detection to the monitor aiming and spraying takes no more than 30 seconds. This fast response helps contain small fires before they spread.
8. Removable Sensor Guard Case Purpose
Q: What's the point of the "removable sensor guard case"?A: The guard case protects the infrared/UV sensors from dust, debris, or physical damage. It's removable so you can easily clean the sensors (to maintain detection accuracy) without disassembling the entire monitor.
9. Suitability for "Harsh Environments"
Q: Can this monitor be used in harsh environments (e.g., industrial areas), and why?A: Yes-its hard anodized surface (resists corrosion/wear) and high-strength, fire-retardant nylon material make it durable for harsh settings (dust, temperature swings, industrial debris). It's built to withstand tough conditions.
10. Benefit of "Integrated Design Without Junction Box"
Q: What's good about the "integrated design (no junction box)"?
A: An integrated design means fewer parts to install, less risk of wiring damage (no external junction box), and a more compact setup. It's easier to install, maintain, and takes up less space.