The forede® FIXED MANUAL MONITOR is a high-quality and reliable piece of equipment that is designed to provide maximum efficiency and performance. With a flow rate of 1200 LPM for Model PS8/20-B and 1800 LPM for Model PS8/30-B, this monitor is capable of handling a wide range of firefighting applications.
With a working pressure of 8 Bar, the forede® FIXED MANUAL MONITOR is able to deliver powerful streams of water to effectively battle fires. The monitor has a maximum reach of 50 meters for Model PS8/20-B and 60 meters for Model PS8/30-B, allowing firefighters to easily and safely combat fires from a distance.
The monitor is designed for easy maneuverability, with a range of motion of -90° to +90° vertically and 360° rotation. This flexibility allows firefighters to quickly and efficiently direct water where it is needed most.
Constructed from durable materials such as hard-coated anodized aluminum alloy, the forede® FIXED MANUAL MONITOR is built to withstand the rigors of firefighting operations. The monitor inlet is a flange 3" BS4504 standard, with other sizes and standards available upon request.
| Model Number |
PS8/20-B |
PS8/30-B |
| Flow Rate |
1200 LPM |
1800 LPM |
| Working Pressure |
8 Bar |
8 Bar |
| Max. Reach @ 8 bar |
50 meters |
60 meters |
| Max Range Of Motion |
-90° to +90° Vertically, 360° Rotation |
| Waterway Size |
2.5"(65mm) |
| Monitor Outlet |
2.5" (65mm) NH male thread |
| Monitor Inlet |
Flange 3" BS4504 is standard ( other sizes & standards are available ) |
| Material |
Monitor & Nozzle - Hard coated anodized aluminium alloy Handwheel - Hard coated anodized aluminium alloy |



1. Geared Handwheel Functions
Q: What do the two geared handwheels on this monitor control?A: The dual handwheels handle separate tasks: one adjusts the 360° horizontal rotation and -90° to +90° vertical angle (for aiming), while the other toggles between straight stream/fog patterns and (for selectable models) adjusts flow rate. The geared design keeps operation smooth, even for high-flow setups.
2. Selectable Flow Rate Operation (PS8/20-40W-B)
Q: How do I switch between 1200/1800/2400 LPM flow rates on the PS8/20-40W-B model?A: A manual flow selector (on the monitor body) lets you toggle between the three preset rates. Just turn the selector to your desired flow-no tools are needed, so you can adapt to small/large fires quickly.
3. Straight Stream vs. 120° Fog Pattern Use Cases
Q: When should I use the straight stream vs. the 120° fog pattern?A: Use straight stream for targeted, long-distance suppression (e.g., large, concentrated blazes). Use the 120° fog pattern for wide-area cooling (to stop fire spread to equipment/structures) or suppressing small, scattered fires.
4. Choosing the Right Model (20/30/40W-B)
Q: How do I pick between PS8/20W-B, PS8/30W-B, and PS8/40W-B?A: Match the model to your coverage needs:
- PS8/20W-B (1200 LPM, 50m reach): Small spaces (e.g., small storage yards)
- PS8/30W-B (1800 LPM, 60m reach): Medium zones (e.g., warehouse bays)
- PS8/40W-B (2400 LPM, 65m reach): Large industrial areas (e.g., factory perimeters)
5. -90° to +90° Vertical & 360° Horizontal Range Benefits
Q: What's the advantage of the -90° to +90° vertical range and 360° rotation?
A: 360° rotation covers the entire surrounding area from one fixed mount. The -90° (full downward) to +90° (full upward) vertical range lets you target ground fires, elevated tanks, or upper-structure blazes-versatile for wall, tank, or ground installations.
6. Flange Standard Matching to Existing Pipes
Q: How do I choose the right flange standard (BS4504/ANSI150/GB) for my pipes?
A: Select the flange standard that matches your site's existing pipe system (e.g., ANSI150 for ANSI-compliant pipes). This ensures a tight, leak-proof connection without extra adapters.
7. Hard Coated Anodized Aluminum Durability
Q: How well does the hard coated aluminum hold up in harsh outdoor/industrial environments?
A: The coating resists scratches, minor impacts, and weathering (rain, dust). It's built for long-term use in tough settings-just wipe the surface with a damp cloth periodically to maintain performance.
8. 120° Max Fog Angle Benefit
Q: Why is the fog angle 120°, and how does that help with fire suppression?
A: A 120° fog angle covers a wide area with one adjustment, making it ideal for cooling large sections of equipment/structures (to prevent fire spread) or suppressing scattered, low-intensity blazes. It maximizes coverage with minimal repositioning.
9. Geared Handwheel Operation Effort
Q: Are the geared handwheels hard to turn, especially for the 2400 LPM model?
A: No-the geared design reduces operation effort, so even the high-flow 2400 LPM model's handwheels turn smoothly. Most users can adjust them easily, even during emergency responses.
10. Routine Maintenance for Geared Components
Q: What routine checks does this monitor need?
A: Every 3-6 months: lubricate the geared handwheel components (use a light, non-corrosive lubricant), inspect the inlet flange gasket for wear (replace if cracked), and clear debris from the nozzle to ensure unobstructed water/fog flow.
Dear Customer,
Before ordering, please contact with our sales team to discuss order information.
If you have any other requirements or wanna know more info about our products, welcome to contact as well. Our Sales team and Technical Department are willing to support you.