Customization: | Available |
---|---|
Sprinkler Installation: | Sidewall |
Sprinkler Head Type: | Closed |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model Number
|
Size
|
K factor
|
Tempurature
|
Response Type
|
Glass Bulb
|
T-ZSTBS-20-57ºC
|
3/4''(DN20)
|
8.0
|
57ºC
|
Standard
|
5mm,Orange
|
T-ZSTBS-20-68ºC
|
3/4''(DN20)
|
8.0
|
68ºC
|
Standard
|
5mm,Red
|
T-ZSTBS-20-79ºC
|
3/4''(DN20)
|
8.0
|
79ºC
|
Standard
|
5mm,Yellow
|
T-ZSTBS-20-93ºC
|
3/4''(DN20)
|
8.0
|
93ºC
|
Standard
|
5mm,Green
|
T-ZSTBS-20-141ºC
|
3/4''(DN20)
|
8.0
|
141ºC
|
Standard
|
5mm,Blue
|
K-ZSTBS-20-57ºC
|
3/4''(DN20)
|
8.0
|
57ºC
|
Quick
|
3mm,Orange
|
K-ZSTBS-20-68ºC
|
3/4''(DN20)
|
8.0
|
68ºC
|
Quick
|
3mm,Red
|
K-ZSTBS-20-79ºC
|
3/4''(DN20)
|
8.0
|
79ºC
|
Quick
|
3mm,Yellow
|
K-ZSTBS-20-93ºC
|
3/4''(DN20)
|
8.0
|
93ºC
|
Quick
|
3mm,Green
|
K-ZSTBS-20-141ºC
|
3/4''(DN20)
|
8.0
|
141ºC
|
Quick
|
3mm,Blue
|
Q1:Are there any specific storage requirements for these fire sprinklers before installation?
A:Before installation, these fire sprinklers should be stored in a dry, clean environment with stable temperature and humidity levels. They should be protected from physical damage, such as impacts or vibrations, and kept away from corrosive substances. Storing them in their original packaging can help maintain their integrity until installation.
2.Q2:Can these fire sprinklers be used in a marine environment?
A:Yes, they can be used in a marine environment, but additional precautions are needed. The high - salt and humid conditions in marine settings can accelerate corrosion. It may be necessary to use corrosion - resistant coatings or materials for the sprinklers, and perform more frequent inspections and maintenance to ensure they remain in good working condition.
3.Q3:How do these fire sprinklers perform in areas with high - altitude and low - pressure conditions?
A:In high - altitude and low - pressure conditions, the performance of these fire sprinklers may be affected. The reduced atmospheric pressure can impact the water flow and spray pattern. However, the sprinklers are designed to operate within a certain pressure range. In such areas, it may be necessary to adjust the water supply pressure or use additional equipment to ensure proper water discharge and fire - suppression effectiveness.
4.Q4:Can these fire sprinklers be retrofitted into a building that already has an older - generation sprinkler system?
A:Retrofitting these fire sprinklers into an older - generation system is possible, but it requires careful assessment. Compatibility with the existing piping, water supply, and system design needs to be verified. The K - factor, size, and operating characteristics of the new sprinklers should align with the capabilities of the existing system. Additionally, local fire codes and regulations regarding retrofits must be adhered to.
5.Q5:What is the expected service life of these fire sprinklers under normal operating conditions?
A:Under normal operating conditions, these fire sprinklers can have a service life of 20 - 25 years. This assumes proper installation, regular maintenance, and operation within their specified temperature and pressure ranges. However, factors like environmental conditions, water quality, and frequency of use can influence their actual lifespan.
6.Q6:Can these fire sprinklers be used in a data - center environment?
A:Yes, they can be used in a data - center environment, but special considerations apply. Data centers require careful fire protection to minimize water damage to sensitive equipment. These sprinklers can be part of a pre - action or dry - pipe sprinkler system in a data center, which helps prevent accidental water discharge. Additionally, proper water - management and drainage systems should be in place to quickly remove any discharged water.
7.Q7:How do these fire sprinklers interact with other fire - suppression measures, such as fire blankets or portable extinguishers?
A:These fire sprinklers are part of an overall fire - suppression strategy and can work in tandem with other measures. Fire blankets and portable extinguishers can be used to suppress small fires in their early stages. If the fire grows beyond the capabilities of these smaller - scale measures, the fire sprinklers will activate to provide more comprehensive fire suppression. They complement each other to enhance overall fire - safety in a building.
8.Q8:Can these fire sprinklers be installed in a building with a high - risk of chemical fires?
A:In a building with a high - risk of chemical fires, these fire sprinklers can be part of the fire - protection system, but additional considerations are necessary. Some chemicals may react with water or be more effectively extinguished by other agents. It may be necessary to combine these sprinklers with specialized fire - suppression systems for chemicals, such as foam - based systems for flammable liquid fires. Also, the sprinklers' materials should be resistant to any corrosive effects of the chemicals present.
9.Q9:How does the color - coding of the glass bulbs assist in the installation and maintenance of these fire sprinklers?
A:The color - coding of the glass bulbs simplifies installation and maintenance. During installation, it allows installers to quickly identify the activation temperature of the sprinkler, ensuring the correct sprinklers are placed in areas with appropriate temperature - sensitivity requirements. In maintenance, it helps technicians visually verify the sprinkler's temperature rating without having to refer to detailed documentation, making inspections more efficient.
10.Q10:Can these fire sprinklers be used in a building with a large - open floor plan?
A:Yes, they can be used in a building with a large - open floor plan. However, proper design and layout are crucial. The sprinklers need to be spaced according to the coverage area specified by the manufacturer, taking into account factors like the ceiling height and the K - factor. Additional sprinklers may be required in larger areas to ensure comprehensive fire - protection coverage.